Home » Entire Product Range » Global Water » Global Water Water Flow Logger FL16S
Global Water ASJ000
AVAILABLE IN STOCK
Prices Start From Call for price
Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.
Catalog Numbers | Model | Description |
ARJ025 |
FL16U-003-025 | USB Flow Logger 0-3′ Range, 25′ Cable |
ASJ000 * | FL16S | SERIAL version for collecting data with most PDAs. The FL16 Water Flow Logger package includes weather-resistant logger unit, non-fouling 0-3 ft sensor with 25 feet of heavy duty cable. |
ARJ000 |
F16U | USB version for collecting data with most laptop/desktop computers. The FL16 Water Flow Logger package includes weather-resistant logger unit, non-fouling 0-3 ft sensor with 25 feet of heavy duty cable. |
AIJ025 |
FL400-003-025 | Flow Sensor 0-3′ Range, 25′ Cable |
AIJ000 |
FL400 | Heavy, streamlined open channel flow sensor for sewer flow monitoring. 0-3 ft water level range. Includes 25 feet of cable. |
AIJ000-015 |
FL400-015-025 | Flow Sensor 0-15′ Range, 25′ Cable |
Accessories |
||
Catalog Numbers | Description | |
AE0000 | WLEXE Extra Water Level Logger Cable Cable length is measured from top of water level recorder to bottom of sensor. FL16 includes 25 feet of cable, and extra cable can be added up to 500 feet. |
|
AIL000 | Cable, Hytrel Vented, 5 Wire, Shielded | |
00-631 | Teflon Cable, Vented | |
ASJ100 | FLMNT Protective Mounting Sleeve – FL16 | |
ARJ050 | FL16U Software Kit Includes Software, Manual, & USB Cable |
Specifications | |
FL16 Water Flow Loggers | |
Memory: | Non-volatile flash memory |
Power: | Two 9VDC Alkaline Batteries |
Battery Life: | Up to 1 year (depending on recording intervals) |
Resolution: | 12 bit |
Moisture Protection: | Silicon coating (prevents damage to electronics from condensation) |
Temperature: | -40° to +185°F (-40° to +85°C) |
Humidity: | 0-95% non-condensing |
Storage Capacity: | 81,759 time and date stamped data points including battery voltage |
Sample Modes: | High Speed (10 samples per second), Fixed Interval (Programmable from 1 sec to >1 year), Logarithmic, Exception |
Data Overwrite: | Select memory wrap or unwrap (unwrap will stop logging data once memory is full) |
Clock: | Synchronizes to the time and date of user’s computer |
Clock Accuracy: | 0.0025% or 1 minute in 1 month |
Clock Format: | Month/Day/Year Hour/Minute/Second |
Enclosure: | 1-7/8 inch dia x 11-1/2 inch length (fits inside a 2 inch well), stainless steel UV protected PVC vented for barometric pressure compensation |
Weight: | 1.6 lbs (0.7 kg) (with battery and 25 ft cable) |
Communication Port: | FL16S: RS-232 4-pin circular connector FL16U: USB Type B Selectable Baud Rates: 9600,19200,28800,38400,57600,115200 |
Global Water Flow Loggers Software | |
Compatible with Microsoft’s Windows 98, ME, 2000, NT, XP, Vista, and 7 Windows and Excel are trademarks of the Microsoft Corporation Tabular Display/Printout Data in standard spreadsheet format (.CSV) Programmable alarm start and stop times Field calibration software and help files included |
|
Water Flow Logger Vented Cable | |
Conductors: | 4 each 22 AWG |
Material: | Marine grade polyurethane jacket, HD polyethylene vent tube, full foil shield |
Shield: | Aluminum Mylar |
Outside Diameter: | 0.307 inch (7.8mm) |
Length: | Standard 25 ft (up to 500 ft from factory) |
Temperature range: | -22 to 185°F (-30° to 85°C) |
Weight: | 0.7 oz/ft (65g/m) |
Water Flow Sensor | |
Sensor Element: | Silicone Diaphragm, Wet/Wet Transducer |
Level Range: | 0-3 ft |
Temperature Range: | 32-122°F (0-50°C) |
Linearity and Hysteresis: | ±0.1% FS |
Accuracy: | |
Level: | ±0.1% FS at constant temperature, ±0.2% over 32° to 70°F (0° to 21.1°C) range |
Temperature: | Smaller of 0.5°F or ±1% of reading |
Overpressure: | 2 x full scale range |
Burst Pressure: | 10 x full scale range |
Resolution: | Infinite (Analog) |
Output Currents: | |
Level: | 4-20mA ±1mA of full scale |
Temperature: | 0-10mA ±1mA full scale |
Supply Voltage: | 10-36VDC |
Current Draw: | Combined level and temperature output currents |
Warm Up Time: | 3 seconds recommended |
Operating Temperature: | 0° (not frozen) to +185°F (-17.8° to 85°C) |
Compensated Temperature Range: | 32° to 70°F (0 to 21.1°C) submerged, automatic barometric |
Compensation Housing: | |
Material: | 316 Stainless Steel Outer Sleeve, PVC diffuser and strain relief |
Size: | 9 inch long x 1 inch dia. (22.9 cm long x 2.54 cm dia.) |
Weight: | ~250g (9oz) |
Bluetooth |
|
Format: | Bluetooth 2.0 SPP (Serial Port Protocol) |
Baud Rate: | Auto Detect up to 115K Baud |
Power: | 9 V Alkaline, approx. 20 hours continuous use |
Current: | 30mA Average |
Range: | 20 Feet Maximum |
Operating Temp: | -40° to +185°F (-40° to +85°C) |
Compatible Software: | Global Logger II version 2.1.5 or higher Global Logger II PDA software version 2.0.1 FL16 Flow Monitor version 2.3.2 |
FEATURES:
Global Water’s FL16 Water Flow Logger revolutionizes flow data collection for applications such as inflow & infiltration studies, stormwater and wastewater collection systems, open channels and a host of other gravity flow systems. The FL16 Water Flow Loggers will record over 81,000 depth, temperature, water flow and velocity readings in sewer and drainage pipes, as well as other open channel applications like flumes, weirs and square channels. The specially engineered, non-fouling water level sensor works in depths as little as ½ inch and allows for deployment in manholes and other difficult to access areas without the need to enter the confined space. The FL16 Water Flow Recorder’s vented water flow sensor is fully encapsulated with marinegrade epoxy. The water flow sensor’s electronics are encapsulated so that moisture can never leak in through O-ring seals or work its way into the vent tube and cause drift or sensor failure, as is the case with many other vented water flow sensors. The vent tube is sealed directly to the wet-wet sensing element, and any moisture that may enter the vent tube from the Water Flow Recorder’s housing will only contact the ceramic parts, not the electronics. FL16 Water Flow Recorder’s user-friendly Windows-based software is tailored specifically for calculating water flows in partially filled sewer and drainage pipes using the Manning’s Equation, with pull-down menus for selecting and entering the necessary information. The Water Flow Recorder software has a unique calibration feature which allows users to view calculated water velocity, compare this to actual measured data, and adjust the water flow parameters to calibrate for the water flow conditions of a specific application. Water flow equations for over 40 standard flumes and weirs are provided, as well as user-definable custom lookup tables which can be used to convert water level to flow for virtually any application. Once configured, all setup and water flow parameters are stored in the Water Flow Recorder’s memory and are uploaded to the software automatically upon connection. This information can also be saved to a file for later use, allowing Water Flow Recorders to be deployed in multiple locations without the need to re-enter the water flow parameters each time the Water Flow Recorders are moved. The Water Flow Recorders operate on two standard 9 volt batteries, which they monitor so you are never caught off guard with dead batteries. A third onboard lithium battery ensures your data will be safe in the event you are unable to change the 9V batteries before they fail. An optional protective housing includes hardware for mounting the Water Flow Recorders to a manhole step or other structure and also allows for easy installation and replacement in the field. Choose the FL16-U Water Flow Loggers for USB interface – best for direct to PC or laptop communication — or the FL16-S Water Flow Logger serial version, which is best for Windows CE or Mobile-based PDA’s. NOTE: The Water Flow Loggers do NOT support the Palm operating system. For more information on supported PDAs click Bluetooth Capability The AK1500 Bluetooth Adaptor was designed to eliminate the need for custom PDA cables to communicate between your PDA and the FL16 Water Flow Loggers. The adaptor connects to the Water Flow Logger’s serial port using the same interface cable provided with the software-cable kit. The interface operates from a single 9 volt battery and is turned on automatically when the cable connects the water flow logger and Bluetooth adapter. Because the Bluetooth module consumes power when turned on, it is recommended that the cable be disconnected from the water flow logger when not in use. A red LED shows the power status and is on continuously while the adaptor is plugged into the water flow logger. There is also a blue LED that shows the status of the Bluetooth connection. |
AVAILABLE IN STOCK
AVAILABLE IN STOCK
AVAILABLE IN STOCK
AVAILABLE IN STOCK