Catalog Numbers Model Description
ARJ025 * FL16U-003-025 USB Flow Logger 0-3′ Range, 25′ Cable

ASJ000
FL16S  
SERIAL version for collecting data with most 
PDAs.  The FL16 Water Flow Logger package includes weather-resistant logger unit, non-fouling 0-3 ft sensor with 25 feet of heavy duty cable.

ARJ000
F16U  
USB version for collecting data with most laptop/desktop computers.    The FL16 Water Flow Logger package includes weather-resistant logger unit, non-fouling 0-3 ft sensor with 25 feet of heavy duty cable.

AIJ025
FL400-003-025 Flow Sensor 0-3′ Range, 25′ Cable

AIJ000
FL400  Heavy, streamlined open channel flow sensor for sewer flow monitoring.  0-3 ft water level range.  Includes 25 feet of cable.

AIJ000-015
FL400-015-025 Flow Sensor 0-15′ Range, 25′ Cable
 
Accessories
Catalog Numbers Description
AE0000 WLEXE  Extra Water Level Logger Cable
Cable length is measured from top of water level recorder to bottom of sensor.  FL16 includes 25 feet of cable, and extra cable can be added up to 500 feet.
AIL000 Cable, Hytrel Vented, 5 Wire, Shielded
00-631 Teflon Cable, Vented 
ASJ100 FLMNT Protective Mounting Sleeve – FL16
ARJ050 FL16U Software Kit Includes Software, Manual, & USB Cable

 

Specifications
FL16 Water Flow Loggers
Memory: Non-volatile flash memory
Power: Two 9VDC Alkaline Batteries
Battery Life: Up to 1 year (depending on recording intervals)
Resolution: 12 bit
Moisture Protection: Silicon coating (prevents damage to electronics from condensation)
Temperature: -40° to +185°F (-40° to +85°C)
Humidity:  0-95% non-condensing
Storage Capacity: 81,759 time and date stamped data points including battery voltage
Sample Modes: High Speed (10 samples per second), Fixed Interval (Programmable from 1 sec to >1 year), Logarithmic, Exception
Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full)
Clock: Synchronizes to the time and date of user’s computer
Clock Accuracy: 0.0025% or 1 minute in 1 month
Clock Format:  Month/Day/Year Hour/Minute/Second
Enclosure:  1-7/8 inch dia x 11-1/2 inch length (fits inside a 2 inch well), stainless steel UV protected PVC vented for barometric pressure compensation
Weight:  1.6 lbs (0.7 kg) (with battery and 25 ft cable)
Communication Port:       FL16S: RS-232 4-pin circular connector
     FL16U: USB Type B
     Selectable Baud Rates:
     9600,19200,28800,38400,57600,115200
Global Water Flow Loggers Software
Compatible with Microsoft’s Windows 98, ME, 2000, NT, XP, Vista, and 7
Windows and Excel are trademarks of the Microsoft Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included
Water Flow Logger Vented Cable
Conductors: 4 each 22 AWG
Material: Marine grade polyurethane jacket, HD polyethylene vent tube, full foil shield
Shield: Aluminum Mylar
Outside Diameter: 0.307 inch (7.8mm)
Length: Standard 25 ft (up to 500 ft from factory)
Temperature range: -22 to 185°F (-30° to 85°C)
Weight: 0.7 oz/ft (65g/m)
Water Flow Sensor
Sensor Element: Silicone Diaphragm, Wet/Wet Transducer
Level Range: 0-3 ft
Temperature Range: 32-122°F (0-50°C)
Linearity and Hysteresis: ±0.1% FS
Accuracy:
            Level: ±0.1% FS at constant temperature, ±0.2% over 32° to 70°F (0° to 21.1°C) range
            Temperature: Smaller of 0.5°F or ±1% of reading
Overpressure: 2 x full scale range
Burst Pressure: 10 x full scale range
Resolution:  Infinite (Analog)
Output Currents:
            Level: 4-20mA ±1mA of full scale
            Temperature:  0-10mA ±1mA full scale
Supply Voltage: 10-36VDC
Current Draw: Combined level and temperature output currents
Warm Up Time:  3 seconds recommended
Operating Temperature: 0° (not frozen) to +185°F (-17.8° to 85°C)
Compensated Temperature Range: 32° to 70°F (0 to 21.1°C) submerged, automatic barometric 
Compensation Housing:
            Material:  316 Stainless Steel Outer Sleeve, PVC diffuser and strain relief
            Size: 9 inch long x 1 inch dia. (22.9 cm long x 2.54 cm dia.)
            Weight: ~250g (9oz)
Bluetooth
Format: Bluetooth 2.0 SPP (Serial Port Protocol)
Baud Rate: Auto Detect up to 115K Baud
Power: 9 V Alkaline, approx. 20 hours continuous use
Current: 30mA Average
Range: 20 Feet Maximum
Operating Temp: -40° to +185°F (-40° to +85°C)
Compatible Software: Global Logger II version 2.1.5 or higher
   Global Logger II PDA software version 2.0.1
   FL16 Flow Monitor version 2.3.2

 

FEATURES:

  • Compact, self-powered and easy to use
  • No confined space entry required for sensor deployment
  • User friendly Windows and PDA software included
  • USB and Serial communication options available
  • PDA software simplifies field data collection
  • User programmable start and stop alarms, engineering units, and field calibration setup

  • Automatic barometric pressure and temperature compensation
  • Wet-wet transducer eliminates vent tube concerns

Global Water’s FL16 Water Flow Logger revolutionizes flow data collection for applications such as inflow & infiltration studies, stormwater and wastewater collection systems, open channels and a host of other gravity flow systems.  The FL16 Water Flow Loggers will record over 81,000 depth, temperature, water flow and velocity readings in sewer and drainage pipes, as well as other open channel applications like flumes, weirs and square channels.  The specially engineered, non-fouling water level sensor works in depths as little as ½ inch and allows for deployment in manholes and other difficult to access areas without the need to enter the confined space.

The FL16 Water Flow Recorder’s vented water flow sensor is fully encapsulated with marinegrade epoxy.  The water flow sensor’s electronics are encapsulated so that moisture can never leak in through O-ring seals or work its way into the vent tube and cause drift or sensor failure, as is the case with many other vented water flow sensors.  The vent tube is sealed directly to the wet-wet sensing element, and any moisture that may enter the vent tube from the Water Flow Recorder’s housing will only contact the ceramic parts, not the electronics.

FL16 Water Flow Recorder’s user-friendly Windows-based software is tailored specifically for calculating water flows in partially filled sewer and drainage pipes using the Manning’s Equation, with pull-down menus for selecting and entering the necessary information.  The Water Flow Recorder software has a unique calibration feature which allows users to view calculated water velocity, compare this to actual measured data, and adjust the water flow parameters to calibrate for the water flow conditions of a specific application.  Water flow equations for over 40 standard flumes and weirs are provided, as well as user-definable custom lookup tables which can be used to convert water level to flow for virtually any application.  Once configured, all setup and water flow parameters are stored in the Water Flow Recorder’s memory and are uploaded to the software automatically upon connection.  This information can also be saved to a file for later use, allowing Water Flow Recorders to be deployed in multiple locations without the need to re-enter the water flow parameters each time the Water Flow Recorders are moved.  The Water Flow Recorders operate on two standard 9 volt batteries, which they monitor so you are never caught off guard with dead batteries.  A third onboard lithium battery ensures your data will be safe in the event you are unable to change the 9V batteries before they fail.  An optional protective housing includes hardware for mounting the Water Flow Recorders to a manhole step or other structure and also allows for easy installation and replacement in the field.

Choose the FL16-U Water Flow Loggers for USB interface – best for direct to PC or laptop communication — or the FL16-S Water Flow Logger serial version, which is best for Windows CE or Mobile-based PDA’s.  NOTE: The Water Flow Loggers do NOT support the Palm operating system.  For more information on supported PDAs click 
HERE.  The FL16 Water Flow Logger package includes the weather-resistant water flow logger unit, non-fouling sensor with 25 feet of heavy duty cable and FL16-ACM software package.

Bluetooth Capability

The AK1500 Bluetooth Adaptor was designed to eliminate the need for custom PDA cables to communicate between your PDA and the FL16 Water Flow Loggers.  The adaptor connects to the Water Flow Logger’s serial port using the same interface cable provided with the software-cable kit.  The interface operates from a single 9 volt battery and is turned on automatically when the cable connects the water flow logger and Bluetooth adapter.  Because the Bluetooth module consumes power when turned on, it is recommended that the cable be disconnected from the water flow logger when not in use.  A red LED shows the power status and is on continuously while the adaptor is plugged into the water flow logger.  There is also a blue LED that shows the status of the Bluetooth connection.

 





Request A Quotation...

Please fill Out Your Details & Any Special Requests