Hanna Instruments Ammonia High Range Photometer with 470 nm LED

Hanna Instruments HI96733

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf HI96733
Ammonia High Range Photometer with 470 nm LED
Hanna Instruments HI96733
 

Description:
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants.

Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water.  Ion Selective electrodes currently used for these measurements require up to 5 minutes for a stable response time, normally last only 3 to 6 months. On the other hand, 3 or 4 Chemical Test Kits using color cubes are needed to cover the full range. The best increment with chemical test kits is never better than 0.1 mg/L and in most cases, only 0.5 mg/L. 

HANNA® offers three instruments for low, medium and high concentrations: HI93700 with a range of 0.00 to 3.00 mg/L, HI93715 from 0.00 to 9.99 mg/L and HI96733 measuring from 0.0 to 50.0 mg/L for applications with higher concentrations.


 
Specifications:
Range
0.0 to 50.0 mg/L
Resolution
0.1 mg/L
Accuracy
±0.5 mg/L ±5% of reading
Light Source
LED 470 nm
Light Life
Life of the instrument
Light Detection
Silicon Photocell
Battery Type / Life
1 x 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use
Environment
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions
180 x 83 x 46 mm (7.1 x 3.3 x 1.8″)
Weight
290 g (10 oz.)
Method
Adaptation of the ASTM Manual of Water and Environmental Technology,
D1426-92, Nessler Method.
The reaction between ammonia and reagents causes a yellow tint in the sample
 
Solutions:

HI93703-50
Solution for Cleaning Cuvets
Accessories:

HI731321
Glass Cuvet for HI937xx & HI832xx Series Meters

HI731325
Cuvet Cap Turbidity Meters & HI937xx Series Meters

HI710009
Shockproof Boot, Blue

HI710010
Shockproof Boot, Orange

HI731318
Tissue for Wiping Cuvets
Reagents & Standards:

HI93700-01
Ammonia LR, Nessler Method (100 Tests)

HI93700-03
Ammonia LR, Nessler Method (300 Tests)

HI93715-01
Ammonia MR, Nessler Method (100 Tests)

HI93715-03
Ammonia MR, Nessler Method (300 Tests)

HI93733-01
Ammonia HR, Nessler Method (100 Tests)

HI93733-03
Ammonia HR, Nessler Method (300 Tests)
 
Order Information:
HI96733 is supplied with 2 cuvets, battery and instructions.
 

Request A Quotation...