Home » Entire Product Range » Photometers » Hanna Instruments Ammonia High Range Photometer with 470 nm LED
Hanna Instruments HI96733
Prices Start From Call for price
Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.
Description:
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants.
Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water. Ion Selective electrodes currently used for these measurements require up to 5 minutes for a stable response time, normally last only 3 to 6 months. On the other hand, 3 or 4 Chemical Test Kits using color cubes are needed to cover the full range. The best increment with chemical test kits is never better than 0.1 mg/L and in most cases, only 0.5 mg/L. HANNA® offers three instruments for low, medium and high concentrations: HI93700 with a range of 0.00 to 3.00 mg/L, HI93715 from 0.00 to 9.99 mg/L and HI96733 measuring from 0.0 to 50.0 mg/L for applications with higher concentrations. |
Range
|
0.0 to 50.0 mg/L
|
Resolution
|
0.1 mg/L
|
Accuracy
|
±0.5 mg/L ±5% of reading
|
Light Source
|
LED 470 nm
|
Light Life
|
Life of the instrument
|
Light Detection
|
Silicon Photocell
|
Battery Type / Life
|
1 x 9V / approx. 40 hours of continuous use;
auto-off after 10 minutes of non use |
Environment
|
0 to 50°C (32 to 122°F); RH max 95% non-condensing
|
Dimensions
|
180 x 83 x 46 mm (7.1 x 3.3 x 1.8″)
|
Weight
|
290 g (10 oz.)
|
Method
|
Adaptation of the ASTM Manual of Water and Environmental Technology,
D1426-92, Nessler Method.
The reaction between ammonia and reagents causes a yellow tint in the sample |
Solutions:
|
|
HI93703-50 |
Solution for Cleaning Cuvets
|
Accessories:
|
|
HI731321 |
Glass Cuvet for HI937xx & HI832xx Series Meters
|
HI731325 |
Cuvet Cap Turbidity Meters & HI937xx Series Meters
|
HI710009 |
Shockproof Boot, Blue
|
HI710010 |
Shockproof Boot, Orange
|
HI731318 |
Tissue for Wiping Cuvets
|
Reagents & Standards:
|
|
HI93700-01 |
Ammonia LR, Nessler Method (100 Tests)
|
HI93700-03 |
Ammonia LR, Nessler Method (300 Tests)
|
HI93715-01 |
Ammonia MR, Nessler Method (100 Tests)
|
HI93715-03 |
Ammonia MR, Nessler Method (300 Tests)
|
HI93733-01 |
Ammonia HR, Nessler Method (100 Tests)
|
HI93733-03 |
Ammonia HR, Nessler Method (300 Tests)
|