Hanna Instruments Ammonia, Low Range, Portable Photometer

Hanna Instruments HI96700

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf HI96700
Ammonia, Low Range, Portable Photometer
Hanna Instruments HI96700
 

Description:
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
The HI96700 meter measures the ammonia-nitrogen (NH3-N) content in water samples.
 
These meters use an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
 
Ammonia is often an excellent indication of the presence of animal or plant microbiological decay. It is tested in fish farms (fresh and salt water tanks) due to the damaging effects of its toxic nature. Its presence in rivers and reservoirs normally points to agricultural and/or civil pollutants. Ammonia is tested in lakes, rivers, portable water, boiler feed water, sewage, industrial and waste water.


 
Specifications:
Range
0.00 to 3.00 mg/L (ppm)
Resolution
0.01 mg/L (ppm)
Accuracy
±0.04 mg/L (ppm) ±4% of reading @ 25°C
Light Source
Tungsten lamp
Light Detector
silicon photocell with narrow band interference filter @ 420 nm
Environment
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply
9V battery
Auto-off
After 10 minutes of non-use in measuring mode After 1 hour of non-use in
calibration mode with last reading reminder
Dimensions
192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
Weight
360 g (12.7 oz.)
Method
Adaptation of the ASTM Manual of Water and Environmental Technology,
D1426-92, Nessler method.
 
Accesories:
Solutions

HI93703-50
Cuvette Cleaning Solution
Accessories

HI731318
Cuvette Cleaning Cloth

HI731331
Glass Cuvette Set

HI731335
Cuvette Cap for HI957xx Series Meters
Reagents & Standards

HI96700-11
CAL CHECK™ standard cuvettes

HI93700-01
Ammonia LR, Nessler Method (100 Tests)

HI93700-03
Ammonia LR, Nessler Method (300 Tests)
 
Order Information:
HI96700
is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.

HI96700C includes photometer, sample cuvettes with caps (2 ea.), 9V battery, cloth for wiping 
cuvettes,
instrument quality certificate, instruction manual and rigid carrying case.
 


Request A Quotation...