Hanna Instruments Chlorine, Cyanuric Acid and pH Portable Photometer for Legionella Protection with Kit

Hanna Instruments HI96725C

AVAILABLE IN STOCK

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf HI96725C
Chlorine, Cyanuric Acid and pH Portable Photometer for Legionella Protection with Kit
Hanna Instruments HI96725C
 

Description:
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
 
Legionella species is the agent that causes human Legionnaires’ disease as well as the lesser form, Pontiac Fever. Transmission is facilitated by the inhalation of mist droplets containing the Legionella bacteria.
 
Common sources of Legionella include cooling towers used in industrial cooling water systems as well as in large central air conditioning systems, domestic hot water systems, fountains, and similar disseminators that draw from a public water supply. Natural sources include freshwater ponds and creeks. Since Legionella is especially harmful to people with weakened immune systems, it should be actively checked for in the water systems of hospitals and nursing homes.
The HI96725 measures 4 parameters that are crucial in monitoring for preventive maintenance or disinfection.


  
Specifications:
Range
Cl, Free
0.00 to 5.00 mg/L (ppm)
 
Cl, Total
0.00 to 5.00 mg/L (ppm)
 
CYA
0 to 80 mg/L (ppm)
 
pH
6.5 to 8.5 pH
Resolution
Cl, Free
0.01 mg/L
 
Cl, Total
0.01 mg/L
 
CYA
1 mg/L (ppm)
 
pH
0.1 pH
Accuracy @25°C
Cl, Free
±0.03 mg/L ±3% of reading
 
Cl, Total
±0.03 mg/L ±3% of reading
 
CYA
±1 mg/L ±15% of reading
 
pH
±0.1 pH
Light Source
 
tungsten lamp
Light Detector
 
silicon photocell with narrow band interference filter @ 525 nm
Power Supply
 
9V battery
Auto-off
 
after ten minutes of non-use in measurement mode; after one hour of
non-use in calibration mode; with last reading reminder
Environment
 
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions
 
192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
Weight
 
360 g (12.7 oz.)
Method
Chlorine
adaptation of the EPA recommended DPD method 330.5
 
CYA
adaptation of the Turbidimetric method
 
pH
Phenol Red method
 
Accessories:
Solutions

HI93703-50
Cuvette Cleaning Solution
Accessories

HI731331
Glass Cuvette Set

HI731335
Cuvette Cap for HI957xx Series Meters

HI731318
Cuvette Cleaning Cloth
Reagents & Standards

HI93701-01
Chlorine, free, DPD Method (100 Tests)

HI93701-03
Chlorine, free, DPD Method (300 Tests)

HI96710-11
CAL CHECK™ standard cuvettes(pH)

HI93710-01
pH, Phenol Red Method (100 Tests)

HI93710-03
pH, Phenol Red Method (300 Tests)

HI93711-01
Chlorine, Total, DPD Method (100 Tests)

HI93711-03
Chlorine, Total, DPD Method (300 Tests)

HI96722-11
CAL CHECK™ standard cuvettes(CYS)

HI93722-01
Cyanuric Acid, Turbidimetric Method (100 Tests)

HI93722-03
Cyanuric Acid, Turbidimetric Method (300 Tests)
 
Order Information:

HI96725 is supplied with sample cuvettes (2) with caps, 9V battery and instruction manual.
HI96725C includes HI96725 photometer, hard carrying case, 2 sample cuvettes, scissors, cuvette cleaning cloth, battery
and instruction manual.
 