Home » Entire Product Range » Photometers » Hanna Instruments Chlorine Dioxide Portable Photometer
Hanna Instruments HI96738
AVAILABLE IN STOCK
Prices Start From Call for price
Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.
Description:
Chlorine dioxide is used primarily as a disinfectant in drinking water and also in various industrial processes. In drinking water applications, it is gaining popularity over chlorine, considering that it does not generate trihalomethanes when reacting with organic compounds. In industrial applications, it is used as a bleaching agent in such applications as pulp and paper.
The HI96738 meter measures the chlorine dioxide content in water samples in the 0.00 to 2.00 mg/L range. This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.
Chlorine Dioxide is a highly effective, eco-friendly microbiocide that carries a number of important regulatory approvals from several international organisations including the US EPA, FDA and UK Government for many of its uses.
Chlorine and bromine react rapidly with microbiological species and chemicals in water. This reactivity is both their strength and weakness. Since chemical reactions are usually the first to take place, only the small residual of the product remaining after the chemical reaction is completed is available for microbiological control.
Chlorine dioxide is a very safe and potent biocide. It is effective over a wide pH range in both hard and soft water and does not react with most other water treatment chemicals.
|
Range
|
0.00 to 2.00 mg/L
|
Resolution
|
0.01 mg/L
|
Accuracy
|
±0.10 mg/L ±5% of reading @ 25°C
|
Light Source
|
Tungsten lamp
|
Light Detector
|
Silicon photocell with narrow band interference filter @ 575 nm
|
Environment
|
0 to 50°C (32 to 122°F); RH max 95% non-condensing
|
Power Supply
|
9V battery
|
Auto-off
|
After 10 minutes of non-use in measurement mode; after 1 hour of non-use in
calibration mode; with last reading reminder.
|
Dimensions
|
192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
|
Weight
|
360 g (12.7 oz.)
|
Method
|
Chlorophenol Red method
|
Solutions
|
|
HI93703-50 |
Cuvette Cleaning Solution
|
Accessories
|
|
HI731318 |
Cuvette Cleaning Cloth
|
HI731331 |
Glass Cuvette Set
|
HI731335 |
Cuvette Cap for HI957xx Series Meters
|
Reagents & Standards
|
|
HI96738-11 |
CAL CHECK™ standard cuvettes
|
HI93738-01 |
Chlorine Dioxide, Chlorophenol Red Method (100 Tests)
|
HI93738-03 |
Chlorine Dioxide, Chlorophenol Red Method (300 Tests)
|
AVAILABLE IN STOCK
AVAILABLE IN STOCK
AVAILABLE IN STOCK
AVAILABLE IN STOCK