Hanna Instruments Chlorine Dioxide Portable Photometer

Hanna Instruments HI96738

AVAILABLE IN STOCK

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf HI96738
Chlorine Dioxide Portable Photometer
Hanna  Instruments HI96738
 

Description:
  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features
Chlorine dioxide is used primarily as a disinfectant in drinking water and also in various industrial processes. In drinking water applications, it is gaining popularity over chlorine, considering that it does not generate trihalomethanes when reacting with organic compounds. In industrial applications, it is used as a bleaching agent in such applications as pulp and paper.
 
The HI96738 meter measures the chlorine dioxide content in water samples in the 0.00 to 2.00 mg/L range.  This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell. 
 
Chlorine Dioxide is a highly effective, eco-friendly microbiocide that carries a number of important regulatory approvals from several international organisations including the US EPA, FDA and UK Government for many of its uses.
 
Chlorine and bromine react rapidly with microbiological species and chemicals in water. This reactivity is both their strength and weakness. Since chemical reactions are usually the first to take place, only the small residual of the product remaining after the chemical reaction is completed is available for microbiological control.
 
Chlorine dioxide is a very safe and potent biocide. It is effective over a wide pH range in both hard and soft water and does not react with most other water treatment chemicals.


  
Specifications:
Range
0.00 to 2.00 mg/L
Resolution
0.01 mg/L
Accuracy
±0.10 mg/L ±5% of reading @ 25°C
Light Source
Tungsten lamp
Light Detector
Silicon photocell with narrow band interference filter @ 575 nm
Environment
0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply
9V battery
Auto-off
After 10 minutes of non-use in measurement mode; after 1 hour of non-use in
calibration mode; with last reading reminder.
Dimensions
192 x 104 x 69 mm (7.6 x 4.1 x 2.7″)
Weight
360 g (12.7 oz.)
Method
Chlorophenol Red method

 

Solutions

HI93703-50
Cuvette Cleaning Solution
Accessories

HI731318
Cuvette Cleaning Cloth

HI731331
Glass Cuvette Set

HI731335
Cuvette Cap for HI957xx Series Meters
Reagents & Standards

HI96738-11
CAL CHECK™ standard cuvettes

HI93738-01
Chlorine Dioxide, Chlorophenol Red Method (100 Tests)

HI93738-03
Chlorine Dioxide, Chlorophenol Red Method (300 Tests)

 

Order Information:
HI96738 is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI96738C is supplied with HI96738 photometer, sample cuvettes with caps (2 ea.), CAL CHECK™ standard cuvettes (2),
9V battery, scissors, cloth for wiping cuvettes, instrument quality certificate, instruction manual and rigid carrying case.
 


Request A Quotation...

Please fill Out Your Details & Any Special Requests