Home » Entire Product Range » Hanna Products » Hanna Instruments Copper Low Range Portable Photometer Kit
Hanna Instruments HI96747C
Prices Start From Call for price
Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.
Description
Copper is an important micronutrient, essential for plant and animal vigor. Copper is also an important and versatile metal utilized in a variety industrial applications such as alloy production, pigments, kitchen utensils, pipes and electrical wires. Copper salts are often employed to control the growth of plankton and algae. In drinking water, concentrations of copper exceeding 1 mg/L can leave a bitter aftertaste.
HI96747 is a robust auto-diagnostic portable photometer engineered to measure a wide range of copper concentrations, from 0.000 to 1.500 mg/L. Thanks to the specially formulated HI96747-01 powder reagent, with long-term stability, copper analysis is possible even where iron and calcium is present, such as in sea water. The advanced optical system of this photometer employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go. Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck to make it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. HI96747 utilizes an adaptation of the USEPA approved bicinchoninate method. The reaction between copper and the bicinchoninate reagent causes a purple tint to the solution. |
Range
|
0.0 to 30.0 mg/L
|
Resolution
|
0.1 mg/L
|
Accuracy
|
±1.0 mg/L ±4% of reading @ 25°C
|
Light Source
|
Tungsten lamp
|
Light Detector
|
Silicon photocell with narrow band interference filter @ 525 nm
|
Method
|
Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th ed.
|
Typical EMC Deviation
|
±0.2 mg/L
|
Environment
|
0 to 50°C (32 to 122°F); max 95% RH non-condensing
|
Battery Type
|
1 x 9 volt
|
Auto-Shut off
|
After 10′ of non-use in measurement mode; after 1 hour of non-use in calibration mode;
|
Dimensions
|
192 x 102 x 67 mm (7.6 x 4 x 2.6″)
|
Weight
|
290 g (10 oz.)
|
Reagents & Standards
|
|
HI95717-11 |
Cal Check® Standard cuvette for HI95717
|
HI93717-01 |
Phosphate HR, Amino Acid Method (100 Tests)
|
HI93717-03 |
Phosphate HR, Amino Acid Method (300 Tests)
|