Home » Entire Product Range » Refractometers » Hanna Instruments Digital Refractometer for Seawater Analysis
Hanna Instruments HI96822
Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.
Description:
Designed for Research Grade Analysis
HANNA‘s HI96822 Digital Refractometer is a rugged portable, water resistant device that utilizes the measurement of the refractive index to determine the salinity of natural and artificial seawater, ocean water or brackish intermediates. The HI96822 benefits from HANNA‘s years of experience as a manufacturer of analytical instruments. This digital refractometer eliminates the uncertainty associated with mechanical refractometers and is rugged and portable enough to be used at home, in the lab and out in the field.
The HI96822 is an optical device that is quick and easy to use. After a simple user calibration with distilled or deionized water, a seawater sample can be introduced into the sample well.
Within seconds, the refractive index and temperature are measured and converted into one of 3 popular measurement units: Practical Salinity Units (PSU), Salinity in parts per thousand (ppt), or Specific Gravity (S.G. (20/20)). All conversion algorithms are based upon respected scientific publications using the physical properties of seawater (not sodium chloride).
Temperature (in °C or °F) is displayed simultaneously with the measurement on the large dual level display along with icons for Low Power and other helpful message codes.
|
Range
|
PSU
|
0 to 50
|
Range
|
ppt
|
0 to 150
|
Range
|
Specific Gravity (20/20)
|
1.000 to 1.114
|
Range
|
Temperature
|
0 to 80°C (32 to 176°F)
|
Resolution
|
PSU
|
1
|
Resolution
|
ppt
|
1
|
Resolution
|
Specific Gravity (20/20)
|
0.001
|
Resolution
|
Temperature
|
±0.1°C (0.1°F)
|
Accuracy (@20°C)
|
PSU
|
±2
|
Accuracy (@20°C)
|
ppt
|
±2
|
Accuracy (@20°C)
|
Specific Gravity (20/20)
|
±0.002
|
Accuracy (@20°C)
|
Temperature
|
±0.3°C (0.5°F)
|
Temperature Compensation
|
|
Automatic between 10 and 40°C (50 to 104°F)
|
Measurement Time
|
|
Approximately 1.5 seconds
|
Minimum Sample Volume
|
|
100 μL (to cover prism totally)
|
Light Source
|
|
Yellow LED
|
Sample Cell
|
|
Stainless steel ring and flint glass prism
|
Auto-off
|
|
After 3 minutes of non-use
|
Enclosure Rating
|
|
IP 65
|
Battery Type / Battery Life
|
|
9V / Approx 5000 readings
|
Dimensions / Weight
|
|