Hanna Instruments Fluoride, Low Range Waterproof Photometer with 575 nm filter and Cal Check

Hanna Instruments HI96729

AVAILABLE IN STOCK

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf HI96729
Fluoride, Low Range Waterproof Photometer with 575 nm filter and Cal Check
Hanna Instruments  HI96729
 

Description:
Fluoride is a natural component of ground water. As a preventative measure against tooth decay, it is also a common additive to city water. But too high concentrations may be harmful. Thus the need to accurately measure its presence in all water for consumption. HI96729 is an auto-diagnostic portable photometer for accurately measuring fluoride from 0.00 to 2.00 mg/L.

The advanced optical system employs a specialized tungsten lamp and a narrow band interference filter, assuring accurate readings. This instrument is equipped with Cal Check® validation function and standards to validate good performance at any time. Taking just a few short steps, the validation procedure is user-friendly and ensures that the meter is properly calibrated wherever you go.



Hanna photometers use the exclusive ready-made, NiST traceable standards to verify the performance of the instrument and recalibrate if necessary. Cuvets are constructed from specialized optical glass to ensure the best and most consistent results. The positive locking system ensures that the cuvet is in the same position every time it is placed into the measuring cell. Our sample cell is designed to fit a cuvet with a wide neck, thus making it easier to add both sample and reagents. All instruments are factory calibrated and the electronic and optical design minimizes the need for frequent calibration. Ideal for field applications, these meters are splash proof and the lamp and filter units are protected from dust or dirt by a transparent barrier. Display messages aid the user during routine operation. The auto-off feature will disengage the meter after 10 minutes of non-use in measuring mode or 1 hour while in calibration mode. 

Note:
Chlorine will interfere with fluoride analysis and taint results. To remedy this, HANNA® suggests the HI93703-53 liquid reagent with dropper to remove chlorine interference. This reagent is very quick and practical to use. Just add a drop for every 2 mg/L of chlorine present in the sample to eliminate its interference.

HI96729 utilizes an adaptation of EPA Method 340.1 and SPADNS Method.


 
Specifications:

Parameter
Fluoride, Low Range
Range
0.00 to 2.00 mg/L
Accuracy
±0.03 mg/L @ 1.00 mg/L
Filter
Narrow band @ 575 nm
Method
Adaptation of the EPA method 340.1 and SPADNS method.
Environment
0 to 50°C (32 to 122°F); Max 95% RH non-condensing
Battery Type / Life
(1) 9V/approx. 200 hours continuous use
Auto Shut-off
After 10 min. of non-use in measurement mode
Dimensions
192 x 102 x 67 mm (7.6 x 4 x 2.6″)
Weight
290 g (10 oz.)
 
Order Information:
HI96729 is supplied with (2) sample cuvets with caps, 9V battery and instruction manual.
 
HI96729C is supplied with CAL CHECK™ standard cuvets, (2) sample cuvets with caps, (1) 2000 µL automatic pipette
with cap, (1) pipette tip, 9V battery, tissue for wiping cuvets and instruction manual in a hard carrying case.
 