BL932700 is an ORP mini controller that has been designed for easy, affordable installation in tight spaces, ideal for simple yet effective process control. As a result of its compact size, BL932700 can be installed right next to tanks or vats.
This versatile controller is ideal for many applications, such as ORP monitoring bleaching processes, waste water treatment and swimming pools. BL932700 permits automatic control of installations previously checked manually.
The instrument can be set for reducing or oxidizing dosage. It measures in the ±1000 mV range, with 1 mV resolution. Set point adjustment and calibration are simply performed through trimmers on the front panel. You can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need.
The overtime control system advises you when the relay is active too long, helping to prevent over dosage. In addition, this model features a 4-20 mA analog output for recorder connection.
Two models are available, with power supply input at 115/230 Vac or 12 Vdc.
|
Range
|
±1000 mV
|
Resolution
|
1 mV
|
Accuracy
|
±5 mV
|
Calibration
|
manual, with CAL trimmer
|
Dosing Relay
|
1, max 2A (fuse protected), 250 Vac, 30 Vdc
|
Dosing Selection
|
reducing or oxidizing
contact open = reducing dosage, activated when reading exceeds setpoint value contact closed = oxidizing dosage; activated when reading falls below setpoint value |
Setpoint
|
adjustable from -1000 to 1000 mV
|
Overtime
|
adjustable, typically from 5 to approx. 30 minutes
|
Recorder Output
|
4-20 mA, accuracy ±0.20 mA, 500 Ohm max load
|
Input Impedance
|
102 Ohm
|
Power Supply
|
See Chart
|
Dimensions
|
83 x 53 x 99 mm (3.3 x 2.1 x 3.9″)
|
Weight
|
See Chart
|
Solutions
|
|
HI7020L |
ORP Test Solution at 200/275 mV (@20°C)
1 x 500 mL bottle |
HI7022L |
ORP Test Solution at 470 mV (@20°C)
1 x 500 mL bottle |
HI7091L |
Reducing Pretreatment Solution
1 x 500 mL bottle |
HI7092L |
Oxidizing Pretreatment Solution
1 x 500 mL bottle |
HI70300L |
Electrode Storage Solution
1 x 500 mL bottle |
HI7061L |
General Purpose Cleaning Solution
1 x 500 mL bottle |
Accessories
|
|
HI710005 |
Voltage adapter from 115V to 12 Vdc (USA plug)
|
HI710006 |
Voltage adapter from 230V to 12 Vdc (European plug)
|
HI740146 |
Bracket for Installation of Process Meters
|