Hanna Instruments ORP Mini Controller with 4-20 mA Recorder Output 12V DC

Hanna Instruments BL932700-0

AVAILABLE IN STOCK

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf BL932700-0
ORP Mini Controller with 4-20 mA Recorder Output 12V DC
Hanna Instruments BL932700-0 / Spectrum 240-72988 
 

Description:
BL932700 is an ORP mini controller that has been designed for easy, affordable installation in tight spaces, ideal for simple yet effective
process control. As a result of its compact size, BL932700 can be installed right next to tanks or vats.
 
This versatile controller is ideal for many applications, such as ORP monitoring bleaching processes, waste water treatment and swimming pools. BL932700 permits automatic control of installations previously checked manually.
 
The instrument can be set for reducing or oxidizing dosage. It measures in the ±1000 mV range, with 1 mV resolution. Set point adjustment and calibration are simply performed through trimmers on the front panel. You can also choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations, because it permits you to enable or disable the dosing relay according to your need.
 
The overtime control system advises you when the relay is active too long, helping to prevent over dosage. In addition, this model features a 4-20 mA analog output for recorder connection.
 
Two models are available, with power supply input at 115/230 Vac or 12 Vdc.


  
Specifications:
Range
±1000 mV
Resolution
1 mV
Accuracy
±5 mV
Calibration
manual, with CAL trimmer
Dosing Relay
1, max 2A (fuse protected), 250 Vac, 30 Vdc
Dosing Selection
reducing or oxidizing
contact open = reducing dosage, activated when reading exceeds setpoint value
contact closed = oxidizing dosage; activated when reading falls below setpoint value

Setpoint
adjustable from -1000 to 1000 mV
Overtime
adjustable, typically from 5 to approx. 30 minutes
Recorder Output
4-20 mA, accuracy ±0.20 mA, 500 Ohm max load
Input Impedance
102 Ohm
Power Supply
See Chart
Dimensions
83 x 53 x 99 mm (3.3 x 2.1 x 3.9″)
Weight
See Chart
 
Accessories:
Solutions

HI7020L
ORP Test Solution at 200/275 mV (@20°C)
1 x 500 mL bottle

HI7022L
ORP Test Solution at 470 mV (@20°C)
1 x 500 mL bottle

HI7091L
Reducing Pretreatment Solution
1 x 500 mL bottle

HI7092L
Oxidizing Pretreatment Solution
1 x 500 mL bottle

HI70300L
Electrode Storage Solution
1 x 500 mL bottle

HI7061L
General Purpose Cleaning Solution
1 x 500 mL bottle
Accessories

HI710005
Voltage adapter from 115V to 12 Vdc (USA plug)

HI710006
Voltage adapter from 230V to 12 Vdc (European plug)

HI740146
Bracket for Installation of Process Meters
 
Order Information:
The BL932700 is supplied with mounting brackets, transparent cover, and instructions.
 

Request A Quotation...

Please fill Out Your Details & Any Special Requests