Home » Entire Product Range » Controllers » Hanna Instruments Panel Mounted Dissolved Oxygen Controller
Hanna Instruments HI8410
Prices Start From Call for price
Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.
Reliable DO ControlThe HI8410 is an extended range panel mounted Dissolved Oxygen (DO) controller that is used to maintain and monitor the concentration of DO in a wide range of applications from wastewater treatment to aquaculture. The HI8410 uses a Galvanic probe and typically require less maintenance than a Polarographic style making it ideal for long term monitoring of aeration basins, ponds, and lakes. The set point for controlling the activation of the relay is adjusted manually by the user. An
alarm relay is also manually adjustable and is based upon a tolerance from the programmed set point. Calibration is single set point and can be done in zero oxygen solution.
The dosage mode: Automatic, Continuous ON or OFF and over dose control by setting the Overtime dosage trimmer. If the dosing relay remains continuously activated for more than the selected dosing time, the alarm relay is activated, the alarm LED will start blinking and the dosing relay will be deactivated. A jumper found on the rear panel can disable the “Over time dosage” function.
”Automatic/Off/manual” dosing selection switch and LED on the front panel. In Automatic mode all the relays are controlled based on the measurement set point and alarm values. In OFF mode the dosing and alarm relays are always deactivated. The dosing LED is OFF (as relay status) and the ALARM LED is in accordance with the instrument set point, input reading, and ALARM.
In ON (Manual) mode the dosing relay is always on. The alarm relay is still enabled. If an alarm occurs the dosing relay remains activated. If the over dose time exceeds the setting during manual mode, the alarm relay remains activated.
The front panel is protected behind a transparent splash-proof cover.
|
Range | 0.0 to 50.0 mg/L (ppm) O2 0 to 600 % O2 -5.0 to 50.0 °C |
Resolution | 0.1 mg/L or 1% ( O2) / 0.1 °C |
Accuracy | ±1% of reading ( O2) / ±0.2 °C |
Input |
High impedance 1012 Ohm; Reference annd Matching pin inputs are
available; 4-20 mA
|
Calibration | Manual, one point, in saturated air |
Temperature Compensation | Automatic, from -5 to 50 °C (23 to 122 °F) |
Salinity Compensation | 0 to 51 g/L (resolution 1 g/L) |
Probe (not included) | HI76409/4 with 4 m cable or HI76409/10 with 10 m cable |
Recorder Output | 0 to 20 mA or 4 to 20 mA (isolated) |
Setpoint and Alarm Relay | 1, isolated, 2A, Max. 240V, resistive load, 1,000,000 strokes |
Setpoint Range | 1 to 600 % O2;0.1 to 50.0 mg/L (ppm) O2 |
Alarm Range | 1.0 to 5.0 mg/L (ppm) O2 |
Hysteresis Range | 0.1 to 1.0 mg/L (ppm) O2 |
Dosing Control | OFF/AUTO/ON with selection switch |
over Dosing Control |
Adjustable, from 5 min to 60 min with knob or Disable by wire strap – on
rear panel
|
Backlight | Continuous ON |
Power Supply | 115 Vac ±10% or 230 Vac ±10%; 50/60 Hz |
Enclosure | Black anodized aluminum body; front-panel with flame retardant ABS; transparent splash-proof front cover |
Environment | -10 to 50°C (14 to 122°F); RH max 95% non-condensing |
Panel Cutout | 141 x 69 mm (5.6 x 2.7″) |
Weight | 1 kg (2.2 lb.) |