6310 Visible and 6315 UV/Vis Scanning Spectrophotometers
• Spectrum scanning across entire range from 320 to 1000nm (6310) or 198 to 1000nm (6315) • Concentration measurements by direct factor or by quantitation using up to 6 standards • Kinetics with real time graphical display of sample and standard • Store up to 50 methods in each mode • Pulsed xenon lamp (6315)
The 6310 and 6315 spectrophotometers introduce scanning, kinetics and quantitation modes to the highly successful 63 series.
The units will meet the demands of a wide range of applications especially those in clinical, veterinary, environmental, general QC and performance testing areas.
With a memory capacity of 50 methods for each mode, the fully open operating system ensures compatibility with reagent kits from most manufacturers as well as enabling full customisation.
Specifications:
Parameter
|
6310
|
6315
|
Wavelength range
|
320 to 1000nm
|
198 to 1000nm
|
Wavelength resolution
|
1nm
|
1nm
|
Wavelength accuracy
|
±2nm
|
±2nm
|
Spectral bandwidth
|
8nm
|
8nm
|
Transmittance
|
0 to 199.9%T
|
0 to 199.9%T
|
Absorbance
|
–0.300 to 1.999A
|
–0.300 to 1.999A
|
Accuracy
|
±1%T
|
±1%T
|
Resolution
|
0.1%T, 0.001A
|
0.1%T, 0.001A
|
Stray light
|
<0.5% at 340nm
|
<0.5% at 340nm
|
Noise
|
<0.001A at 0A at 400nm
|
<0.001A at 0A at 400nm
|
Stability
|
<0.002A/h after 30 minutes
|
<0.002A/h after 30 minutes
|
Concentration range
|
–300 to 1999
|
–300 to 1999
|
Concentration resolution
|
Selectable 1, 0.1, 0.01 or 0.001
|
Selectable 1, 0.1, 0.01 or 0.001
|
Calibration
|
Blank with a single standard or factor
|
Blank with a single standard or factor
|
Quantitation range
|
–300 to 1999
|
–300 to 1999
|
Quantitation resolution
|
Selectable 1, 0.1, 0.01 or 0.001
|
Selectable 1, 0.1, 0.01 or 0.001
|
Calibration
|
Blank with up to 6 standards
|
Blank with up to 6 standards
|
Curve correction
|
Linear regression, interpolation or linear regression through zero
|
Linear regression, interpolation or linear regression through zero
|
Kinetics display
|
Graphical and calculated concentration value
|
Graphical and calculated concentration value
|
Calibration
|
Against standard and factor
|
Against standard and factor
|
Correlation factor
|
r2 value displayed with result
|
r2 value displayed with result
|
Spectrum range
|
Any range between 320 and 1000nm
|
Any range between 198 and 1000nm
|
Scan interval
|
1, 2 or 5nm, selectable
|
1, 2 or 5nm, selectable
|
Analysis
|
Absorbance and wavelength of peaks and valleys
|
Absorbance and wavelength of peaks and valleys
|
GLP
|
Real time clock and calendar, Operator ID. Supervisor security (locks all set up parameters). Method display lock
|
Real time clock and calendar, Operator ID. Supervisor security (locks all set up parameters). Method display lock
|
Light source
|
Tungsten halogen lamp
|
Xenon lamp
|
Outputs
|
Analogue and RS232
|
Analogue and RS232
|
Power
|
<50W
|
<50W
|
Size (w x d x h)
|
365 x 272 x 160mm
|
365 x 272 x 160mm
|
Weight
|
6kg
|
6kg
|
Ordering Information:
Catalog Number
|
Description
|
631-001 230V
|
6310 visible, scanning spectrophotometer supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, interface cable and PC application software on CD-ROM* (230V/50Hz and 110V/60Hz)
|
631-501 230V
|
6315 UV/visible scanning spectrophotometer supplied with mains lead, pack 100 disposable cuvettes, 10 x 10mm cell holder, interface cable and PC application software on CD-ROM* (230V/50Hz and 110V/60Hz)
|