Koehler Instrument Automatic Aniline Point Apparatus ASTM D611 230V

Koehler Instrument K10290

AVAILABLE IN STOCK

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf K10290
Automatic Aniline Point Apparatus ASTM D611 230V
Koehler K10290 / VWR 37000-018
Performs aniline point and mixed aniline point determinations automatically by means of a modified thin film technique (ASTM D611 Method E). The sample-aniline mixture is directly heated by a platinum immersion heater and the aniline point is detected photoelectrically. Temperature is displayed on a large LED indicator. Built-in pressure regulator and solenoid valve permit the use of cooling air for quicker cooling cycles or to determine subambient aniline point temperatures. Aniline points as low as 0°C (32°F) can be determined with the use of refrigerated cooling air. Equipped with variable controls for heater, light source and stirrer speed. Cabinet exterior surfaces have a chemical resistant polyurethane enamel finish.

Test Method
Aniline point is used to characterize pure hydrocarbons and to indicate the aromatic content of hydrocarbon mixtures. Equal volumes of aniline and sample or sample plus n-heptane are stirred together while being heated at a controlled rate. After the two phases become miscible, the mixture is cooled at a controlled rate and the temperature at which the two phases separate is the aniline point or mixed aniline point of the sample.

Features

  • Conforms to ASTM D611 and related specifications
  • For samples ranging from clear to very dark
  • Temperature range 0°C to 150°C (32°F to 302°F)
  • Digital temperature display

Included Accessories

  • Standard Borosilicate Glass Test Cell with drain

Specifications

  • Conforms to the specifications of: ASTM D611; IP 2; ISO 2977; DIN 51775; FTM 791-3601; NF M 07-021
  • Testing Range: 0 to 150°C (32 to 302°F)
  • Temperature Display: 0-999.9°C

Electrical Requirements

  • 115V 60Hz, Single Phase, 0.4A
  • 220-240V 50/60Hz, Single Phase, 0.2A

Shipping Information
Shipping Weight: 46 lbs (20.9 kg)
Dimensions: 28x24x20 in. (71.2×61.0x50.8 cm)

 

Catalog Number Description Voltage
K10200 Automatic Aniline Point Apparatus 115V 50/60Hz
K10290 * Automatic Aniline Point Apparatus 220-240V 50/60Hz