Koehler Instrument Rapid Flash Open-Cup Tester 230V K16593 *

Koehler Instrument K16593

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Link Gulf K16593
Rapid Flash Open-Cup Tester 230V K16593
Koehler K16593 * for International Destinations / VWR 37000-112

 


 

Test Method
Verifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C.

Features and Benefits
• Conforms to ASTM D3278, D3828, D4206; DOT CFR 49-173.115; IATA;ISO 9038 and related specifications
• One minute test with a 2mL sample
• Simple to operate

 


 

K16500 Rapid Flash Tester
Rapid Tester® provides rapid determinations of flash point or sustained burning qualities by using a small sample. A flash/no flash test result is achieved in one minute for flash points below 212°F (100°C) with a 2mL sample. Ideally suited for quality assurance and environmental compliance testing as well as actual flashpoint for paints, fragrances, hydrocarbons and other liquids. Open cup models are used for determining sustained burning qualities characteristics of mixtures of flammable and nonflammable liquids or liquids with widely different flash points when assessing flammability characteristics. Features convenient semi-automatic operation for flash/no flash tests. Set the test temperature on the digital display and inject a 2mL or 4mL sample into the sample cup. The tester quickly stabilizes itself at the desired value, permitting the test flame to be applied and the result to be observed by the operator. Unit also performs conventional determinations of actual flash temperature by the small scale closed tester method.
Two models are offered: the Closed Cup Model is for routine flash point tests in the range from –30 to +300°C (–22 to +572°F); the Open-Cup Model is for sustained burning tests in the range from ambient to 212°F (100°C). Both models include automatic temperature control with °C/°F selector switch, syringe, electronic timer, integral NIST traceable thermometer, and an external hose adapter valve for connection to a customer-supplied fuel cylinder or other fuel source.

Specifications
Conforms to the specifications of: ASTM D3278, D3828, D4206; IP 303; ISO 3679, ISO 3680, ISO 9038; DOT CFR 49-173.115; IATA

Included Accessories
Thermometer, range 32 to 572°F (0 to 300°C) Syringe

Dimensions lxwxh,in.(cm)
15×23.4×6.3 (38.1×8.6×16.2)
Net Weight: 10 lbs (4.6kg)

Shipping Information Shipping Weight: 16 lbs (7.26kg)
Dimensions: 2.3 Cu. ft.

 


 


Ordering Information
 

Catalog Number
Product Description
Electrical Requirements

K16500
Rapid Flash Tester, Closed Cup Aluminum Test Cup/Brass Lid & Shutter
115V

K16591
Rapid Flash Tester, Closed Cup Aluminum Test Cup/Brass Lid & Shutter
220-240V

K16502
Rapid Flash Tester, Closed Cup Stainless Steel Test Cup/Lid & Shutter
115V

K16592
Rapid Flash Tester, Closed Cup Stainless Steel Test Cup/Lid & Shutter
220-240V

K16503
Rapid Flash Tester, Open-Cup Aluminum Test Cup
115V
K16593 * Rapid Flash Tester, Open-Cup Aluminum Test Cup
220-240V

K16504
Rapid Flash Tester, Open-Cup Stainless Steel Test Cup
115V

K16594
Rapid Flash Tester, Open-Cup Stainless Steel Test Cup
220-240V

 


 


Accessories
 

Catalog Number
Product Description
Temperature Range
K16506
Fuel Cylinder Valve
K16507
Heat Transfer Compound for thermometer
K16508 Metal Cooling Block to facilitate cooling of the sample cup between tests
K16509 Refrigerant Charged Cooling block to hold cooling mixture for subambient testing
K16510 Syringe 2mL/4mL
K16511 Thermometer
32 to 572°F/0 to 300°C
K16512 Thermometer
32 to 230°F
K16513 Thermometer
212 to 572°F
K16514 Thermometer
0 to 110°C
K16515 Thermometer
100 to 300°C
K16516 Thermometer
-36 to +105°F
K16517 Thermometer
-38 to +40°C

 

Request A Quotation...

Please fill Out Your Details & Any Special Requests