Koehler Instrument K10992 – Solid Block Oxidation Bath

The constant-temperature oil bath holds pressure vessels at the correct depth for grease oxidation stability testing. Microprocessor PID control stabilises temperature quickly without overshoot. An overtemperature circuit interrupts power if the bath exceeds the programmed limit.

Dual LED displays show actual and setpoint temperatures in °C or °F. Optional features include RS232 communications, ramp-to-set control, and advanced functions. The insulated stainless steel bath includes a vessel rack and overflow drain. A corrosion-resistant polyurethane enamel finish protects the steel exterior.

Request a Quote

Prices shown are for the United Arab Emirates only and exclude VAT @ 5% Local Rate (Unless Otherwise Stated).
Other countries may incur additional import duties.

Please Contact Us for further details and pricing for your country or location.

Koehler Instrument K10992 – Solid Block Oxidation Bath

Oxidation Bath

The constant-temperature oil bath holds pressure vessels at the correct depth for grease oxidation stability testing. Microprocessor PID control stabilises temperature quickly without overshoot. An overtemperature circuit interrupts power if the bath exceeds the programmed limit.

Dual LED displays show actual and setpoint temperatures in °C or °F. Optional features include RS232 communications, ramp-to-set control, and advanced functions.

The insulated stainless steel bath includes a vessel rack and overflow drain. A corrosion-resistant polyurethane enamel finish protects the steel exterior.

Oxidation Pressure Vessel

The stainless steel pressure vessel includes a body, lid, stem, needle valve, and dish holder. All internal surfaces feature a high polish for easy cleaning.

The vessel safely withstands 180 psi at 99 °C. The assembly includes three PTFE gasket seals and cap screws with a wrench. Optional PTFE-fluorocarbon seals are also available.

Pressure Measurement and Recording Equipment

Users may select mechanical gauges or the Oxidata® Pressure Management System. The pressure gauge measures vessel pressure with better than 0.5 psi accuracy. The gauge meets ASTM specifications and supports oxygen service. Its range spans 0–160 psi, with 1 psi graduations.

Oxidata® Pressure Measurement System

The Oxidata® system provides electronic pressure measurement using Windows®-based software. It records pressure versus time with better than 0.5 psi accuracy.

The system supports four channels across a 0–200 psi range. Graphical and tabular formats present the recorded data. An RTD attachment measures and reports bath temperature.

The system includes transducers, data acquisition hardware, software, probes, and cables.

Test Method:

The sample is oxidised in a pressure vessel initially charged with oxygen at 110psi (758kPa) and maintained at elevated temperature for a specified ageing period. The pressure drop inside the pressure vessel is measured by means of a gauge or transducer.
Features:

  • Conforms to ASTM D942 and related specifications
  • Four-sample testing capability
  • Available Oxidata® Pressure Measurement System

Conforms to the specifications of: ASTM D942; IP 142; DIN 51808; Federal Testing Method TM 791-3453

Oxidation Bath: Capacity: four (4) oxidation pressure vessels

Temperature Range: ambient to 275°F (135°C)

Bath Medium: 12.5 gal (47.3L) white technical oil

Electrical Requirements:

  • 115V 60Hz, Single Phase, 13.0A
  • 220-240V 50/60Hz, Single Phase, 6.8A

 

Catalog Number Description Voltage
K10901 Oxidation Bath 115V/60Hz
K10991 Oxidation Bath 230V/60Hz
K10902 Solid Block Oxidation Bath 115V/60Hz
K10992 Solid Block Oxidation Bath 230V/60Hz
K11000 Oxidation pressure vessel