Lamotte SMART Spectro 2 Spectrophotometer 110V/220V

Lamotte 2000-02

AVAILABLE IN STOCK

Prices Start From Call for price

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Clarkson 2000-02
SMART® Spectro 2 Spectrophotometer 110V/220V
LaMotte 2000-02 /  Fisher 22-307-836A 
 
Why So SMART?
So easy to use
Menu driven with over 80 pre-programmed tests
Have it your way
Select and customize your own test sequences
Wide wavelength range
350-1000 nm
Superior accuracy
±2 nm continuous accuracy
Automation
Select a test and the precise wavelength is ready
Great memory
Store 25 user calibrations and datalog results

The SMART Spectro is a portable spectrophotometer that is easier to use and more accurate than anything in its price range. With automatic wavelength selection, pre-programmed tests, and superior performance – this is the best spectrophotometer for the money!

Over 80 pre-programmed tests included, and 25 user calibrations can be entered into the memory. The user can also customize sequences for frequently run tests.

Advanced Features:

  • A wider wavelength range
  • Menu-driven display
  • 80 pre-programmed tests with 25 user tests
  • Automatic wavelength selection
  • Unique optical design system using a 1200 lines/mm grating
  • Greater accuracy, higher resolution
  • The SMART Spectro is supplied with 6 sample tubes (25mm round), 2 sample cell holders (25mm round and COD, 10 mm cuvettes), AC adapter, battery charger, instruction manual including test procedures, and quick start guides.
 

Menu Display

Menu Driven Display

Tests and functions are selected from scrolling menus for ultimate simplicity. Results are displayed as %T, absorbance, and concentration.

Pre-Programmed Tests, User Tests & Automatic Wavelength Selection

Over 40 pre-programmed tests. Up to 25 calibrations for additional tests can be entered into the memory. The user can also customize sequences for frequently run tests. The meter automatically goes to the required wavelength.

 

Calibration Curve Calibration Curve
Fully functional spectrophotometer allows the user to select the optimum wavelength for creating calibration curves. The user calibration software automatically calculates the best straight line fit.

 

 Optical System Design

 UNIQUE OPTICAL SYSTEM DESIGN using a 1200 lines/mm grating provides for an excellent range, greater accuracy, and high resolution.

  

All Ready to Go!

The SMART Spectro is supplied with 6 sample tubes, 2 sample cell holders, AC adapter, battery charger, instruction manual including test procedures, and quick-start guides.

 

Specifications:
Wavelength Range: 350-1000 nm
Wavelength Accuracy: ±2 nm
Wavelength Resolution: 1 nm
Wavelength Bandwidth: 5 nm (max)
Photometric Range: 0-125%T, -0.1-2.5A
Photometric Accuracy: ±0.005A
Photometric Noice: <0.001A at 0A,<0.002A at 2A
Photometric Drift: ±0.002A/hr @500 nm
Photometric Stray Light: <0.5 %T
Dispersive Device: Grating – based system
Optical Mount: Modified Ebert
Grating: 1200 grooves/mm ruled grating
Light Source: Quartz halogen
Bulb Life: 1000 hours minimum
Sample Chambers: 25 mm round cell, 10 mm square cuvette UDV, COD
Detector: Silicon photodiode
Temperature Range: 0-40°C
Modes Conc., %T, ABS
Pre-Programmed Tests: Yes
Wavelength Selection: Automatic
User Tests: Yes, up to 25 can be entered and edited
Datalogging: Yes, RS-232
Diagnostics: Yes
Power: 110/220 volt or battery pack (rechargeable)
Weight: 4.65 kgs (10.3 lbs)
Size (W x D x H): 35 cm x 28 cm x 17 cm
 

Item Description
Order Code
SMART® Spectro Spectrophotometer, 120V/220V/60Hz

2000-02

SMART® Spectro Spectrophotometer, 220V/50Hz

2000-EX2
discontinued

Carrying Case

2000-CS

Battery Pack with holder (rechargeable)

2000-BP

SMARTLink 2 Software with cable

1912-3 or 1912-CD

SMART Spectro Spectrophotometer is a registered trademark of LaMotte Company.


 

SMART Spectro Reagent Systems

Test Factor
Range ppm
Test Method (# of reagents)
# of Tests
Case Size*
Order Code
Alkalinity UDV† 15-200 UDV (1) 50 E 4318-J
Aluminum 0.01-0.30 Eriochrome Cyanine R (4) 50 C 3641-SC
Ammonia Nitrogen-LR (Fresh Water) 0.02-1.00 Salicylate (3) 25 A 3659-01-SC
Ammonia Nitrogen-LR (Salt Water) 0.10-1.00 Salicylate (3) 25 A 3659-01-SC
Ammonia Nitrogen HR 0.05-4.00 Nesslerization (2) 50 A 3642-SC
Biquanide 5-70 Colorimetric 50 A 4044
Boron 0.05-0.80 Azomethine-H (2) 50 D 4868
Bromine LR 0.04-9.00 DPD Tablets (3) 100 A 3643-SC
Bromine UDV† 0.3-22.00 Unit Dose Vial (1) 50 E 4311-H
Cadmium 0.02-1.00 PAN (4) 50 E 4017
Carbohydrazide 0.005-0.900 Iron Reduction (3) 100 E 4857
Chloride TesTab 0.5-30.0 Argentometric (1) 50 A 3693-SC
Chlorine 0.02-4.00 DPD Tablets (3) 100 A 3643-SC
Chlorine Free UDV† 0.10-10.00 DPD (1) 50 E 4311-H
Chlorine Liquid DPD 0.025-4.00 DPD (3) 144 A 4859
Chlorine Total UDV† 0.1-10.00 DPD (1) 50 E 4312-H
Chlorine Dioxide 0.04-7.00 DPD tablet/Glycine (2) 50 A 3644-SC
Chromium Hexavalent 0.01-1.00 Diphenylcarbohydrazide (1) 100 A 3645-SC
Chromium TesTab 0.03-1.00 Diphenylcarbohydrazide (1) 50 A 3697-SC
Chromium (Total, Hex & Trivalent) 0.01-1.00 Diphenylcarbohydrazide (5) 100 D 3698-SC
Cobalt 0.02-2.00 PAN (3) 50 D 4851
COD LR  0-150 with Mercury‡ 5-150 Digestion (1) 25 D 0075-SC
COD LR 0-150 without Mercury‡ 5-150 Digestion (1) 25 D 0072-SC
COD SR  0-1500 with Mercury‡ 50-1,500 Digestion (1) 25 D 0076-SC
COD SR  0-1500 without Mercury‡ 50-1,500 Digestion (1) 25 D 0073-SC
COD HR  0-15,000 with Mercury‡ 500-15,000 Digestion (1) 25 D 0077-SC
COD HR  0-15,000 without Mercury‡ 500-15,000 Digestion (1) 25 D 0074-SC
Color 10-1,000 Platinum Cobalt  (0) ¥ NA
Copper BCA – LR 0.05-3.50 Bicinchoninic Acid (1) 50 A 3640-SC
Copper Cuprizone 0.01-2.00 Cuprizone (2) 50 A 4023
Copper DDC 0.05-6.00 Diethyldithiocarbamate (1) 100 A 3646-SC
Copper UDV† 0.20-4.00 UDV, Bicinchoninic acid (1) 50 E 4314-H
Cyanide 0.05-0.50 Pyridine-Barbituric Acid (5) 50 C 3660-SC
Cyanuric Acid 16-200 Melamine (1) 100 C 3661-SC
Cyanuric Acid UDV† 5-150 Melamine, UDV (1) 50 E 4313-H
DEHA 0.005-0.700 Iron Reduction (3) 100 A 4857
Dissolved Oxygen (DO) 0.25-12.0 Winkler Colorimetric (3) 100 A 3688-SC
Erythorbic Acid 0.02-3.00 Iron Reduction (3) 100 A 4857
Fluoride 0.05-2.00 SPADNS (2) 50 B 3647-01-SC
Hardness (total) UDV 10-500 UDV 50 E 4309-H
Hydrazine 0.010-0.750 p-dimethylaminobenzaldehyde (2) 25 A 3656-SC
Hydrogen Peroxide LR 0.02-1.50 DPD Tablets (2) 100 A 3662-SC
Hydrogen Peroxide HR 1-60 DPD 100 B 4045
Hydrogen Peroxide Shock 4-225 DPD 100 B 4045
Hydroquinone 0.01-1.80 Iron Reduction (3) 100 A 4857
Iodine 0.08-14.00 DPD Tablets (2) 100 A 3643-SC
Iron 0.06-6.00 Bipyridyl (2) 50 A 3648-SC
Iron UDV† 0.07-10.00 Bipyridyl UDV (1) 50 E 4315-H
Iron Phenanthroline 0.04-4.50 1,10 Phenanthroline (2) 50 A 3668-SC
Lead 0.1-5.0 PAR (5) 50 D 4031
Manganese LR 0.02-0.70 PAN (3) 50 B 3658-SC
Manganese HR 0.3-15.0 Periodate (2) 50 A 3669-SC
Mercury 0.02-1.50 TMK (3) 50 D 4861
Methylethylketoxime 0.02-3.00 Iron Reduction (3) 100 A 4857
Molybdenum HR 0.2-15.0 Thioglycolate (3) 50 B 3699-02-SC
Nickel 0.06-8.00 Dimethylglyoxime (6) 50 D 3663-SC
Nitrate Nitrogen LR 0.05-3.00 Cadmium Reduction (2) 20 A 3649-SC
Nitrate TesTab 2.5-60 Zinc Reduction (1) 50 A 3689-SC
Nitrite Nitrogen LR 0.20-3.00 Diazotization (2) 20 A 3650-SC
Nitrite TesTab 0.025-1.25 Diazotization (1) 50 A 3886-SC
Nitrogen, Total‡ 2-25 Chromotropic Acid and Perfulfate Digestion 25 D 4026
Ozone LR 0.02-0.40 Indigo Trisulfonate (3) 100 D 3651-SC
Ozone HR 0.00-1.50 Indigo Trisulfonate (3) 20 D 3651-SC
pH CPR (Chlorphenol Red) 5.0-7.0 Colorimetric (3) 100 B 3700-SC
pH PR (Phenol Red) 6.6-8.4 Colorimetric (3) 100 B 3700-SC
pH TB (Thymol Blue) 8.0-9.5 Colorimetric (3) 100 B 3700-SC
Phenol 0.05-6.00 4-Aminoantipyrine (3) 50 B 3652-SC
Phosphate LR‡ 0.04-3.00 Ascorbic Acid Reduction (2) 50 A 3653-SC
Phosphate HR‡ 1.0-70.0 Vanadomolybdophosphoric Acid (1) 50 A 3655-SC
Phosphorus, Total LR 0.07-3.50 Ascorbic Acid and Persulfate Digestion 25 D 4024
Phosphorus, Total HR 5-10 Molybdovanadate and Persulfate Digestion 25 D 4025
Potassium 0.5-10.0 Tetraphenylboron (2) 100 A 3639-SC
Silica LR 0.03-2.50 Heteropoly Blue (4) 50 A 3664-SC
Silica HR 1-50 Silicomolybdate (3) 50 A 3687-SC
Sulfate 5-100 Barium Chloride (1) 50 A 3665-SC
Sulfide LR 0.02-1.00 Methylene Blue (3) 50 B 3654-01-SC
Surfactants 0.5-8.0 Bromphenol Blue (3) 50 D 4876
Tannin 0.2-10.0 Tungstomolybdophosphoric Acid (2) 50 B 3666-SC
Turbidity** 2-400 Absorptimetric (0) ¥ NA
Zinc LR 0.025-3.00 Zincon (6) 50 D 3667-SC

†Requires Accessory Package Code Number 1961 or 1962.

‡Requires Heater Block.

** Not EPA Compliant

*Case Type:
A: 7 x 7 x 10 cm
B: 14.5 x 6.5 x 13 cm
C: 14.5 x 9.5 x 13.5 cm
D: Stand-alone cases. Will not fit into optional field carrying cases.
E: 13 x 7 x 12.5 cm

 

Request A Quotation...

Please fill Out Your Details & Any Special Requests