The T9DCS uses a double monochromator spectrometer with a fixed cell holder and a wavelength range of 185–900 nm. Users can define the bandpass from 0.1 to 5.0 nm in precise 0.1 nm increments. The system achieves stray light lower than 0.0001%T, ensuring highly accurate measurements. Control the instrument easily through USB, RS232, or Wi-Fi connections.
The Persee Analytics T9DCS Spectrophotometer employs dual monochromator technology for demanding UV-Visible spectroscopy applications. The optical design of both T9DCS and T10DCS ensures extremely low stray light characteristics (≤0.00004%T at 220 nm). This design supports an extensive photometric range of -8.0 to +8.0 Abs. With nitrogen-purged optics, the instrument performs measurements at deep ultraviolet wavelengths.
Users can adjust the slit continuously for precise spectral resolution control. An attenuating wheel allows accurate beam size adjustment to match sample requirements.
Model | T9DCS | T10DCS |
Optical System | Double beam | Double beam |
Scan Speed | 1000 nm/min 1500 nm/min location speed |
1000 nm/min 1500 nm/min location speed |
Wavelength Range | 185-900 nm | 185-900 nm |
Wavelength Accuracy | ±0.2 nm | ±0.2 nm |
Spectral Bandwidth | ±20 % (0.1 nm-5 nm continuously adjustable) | ±20 % (0.1 nm-5 nm continuously adjustable) |
Photometric Mode | Transmittance, Absorbance, Energy and Concentration | Transmittance, Absorbance, Energy and Concentration |
Photometric Range | -6.0 Abs-6.0 Abs | -8.0 Abs-8.0 Abs |
Photometric Accuracy | ±0.004 [email protected] A ±0.003 [email protected] A ±0.002 [email protected] A ±0.3 % |
±0.004 [email protected] A ±0.003 [email protected] A ±0.002 [email protected] A ±0.3 % |
Photometric Reproducibility | ≤0.002 [email protected] A ≤0.0008 A/1.0 A ≤0.0004 A/0.5 A ≤0.1 % |
≤0.002 [email protected] A ≤0.0008 A/1.0 A ≤0.0004 A/0.5 A ≤0.1 % |
Photometric Noise | 0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
0 % Noise: ≤0.01 % 100 % Noise: ≤0.1 % |
Baseline Flatness | ±0.0008 Abs | ±0.0005 Abs |
Baseline Stability | 0.1 %/hr | 0.1 %/hr |
Stray light | ≤0.0001 %T (NaI, 220 nm) ≤0.0001 %T (NaNO2, 360 nm) |
≤0.00004 %T (NaI, 220 nm) ≤0.00002 %T (NaNO2, 360 nm) |
Cell Holder | Automatic 8 Cell Changer | Automatic 8 Cell Changer |
Detector | Photo multiplier tube | Photo multiplier tube |
Light Source | D2 lamp, Tungsten lamp, Mercury lamp for WL correction | D2 lamp, Tungsten lamp, Mercury lamp for WL correction |
PC Interface | RS232, USB, Wifi | RS232, USB, Wifi |
Software Support | UV Win | UV Win |
Power Supply | Switchable 120-230 VAC 50-60 Hz | Switchable 120-230 VAC 50-60 Hz |
Weight | 136 lb | 136 lb |
Dimensions | 36 x 25 x 12 in | 36 x 25 x 12 in |