Persee Analytics Vis Spectrophotometer Visible 50/60Hz

Persee Analytics Vis Spectrophotometer Visible 110V 50/60Hz
Persee Analytics T6-1611E / Link Gulf T6-1611E

Designed for accuracy and performance in a compact design the T6 Series of UV-Vis Spectrophotometers offer wavelength accuracy as low as +/- 1 nm combined with low stray light of less than 0.05%T.  With a focus on reliability in a compact footprint, Persee’s entry-level Spectrometers set a new bar for value and capability.

Persee delivers the capabilities required by customers in education, agricultural, environmental and food & beverage industries, all the options and services at such value that customers can get months of consumables or additional instrumentation within their budget without sacrificing performance.

Key Features

  • High-performance fixed 2nm spectral bandwidth
  • Low stray light 0.05%T (T6U)
  • Wavelength accuracy +/- 1nm (T6U)
  • Supplied with either universal pathlength 5 cell changer or fixed path length 8 cell changer as standard
  • Holographic blazed grating 1200lines/mm
  • Local control software for photometric fixed wavelength measurement
  • Easily upgraded to include quantitative analysis, multi-wavelength spectrum & kinetics
  • Built-in cell holder storage
  • Robust modular design with a small footprint
  • Can be used with UV-WIN software (optional)

REQUEST A QUOTE

Prices shown are for the United Arab Emirates only and are excluding VAT @ 5% Local Rate (Unless Otherwise Stated).

Other countries may incur additional import duties – Please Contact Us for further details and pricing for your location.

Persee Analytics Vis Spectrophotometer Visible 110V 50/60Hz
Persee Analytics T6-1611E / Link Gulf T6-1611E

Designed for accuracy and performance in a compact design the T6 Series of UV-Vis Spectrophotometers offer wavelength accuracy as low as +/- 1 nm combined with low stray light of less than 0.05%T.  With a focus on reliability in a compact footprint, Persee’s entry-level Spectrometers set a new bar for value and capability.

Persee delivers the capabilities required by customers in education, agricultural, environmental and food & beverage industries, all the options and services at such value that customers can get months of consumables or additional instrumentation within their budget without sacrificing performance.

Key Features

  • High-performance fixed 2nm spectral bandwidth
  • Low stray light 0.05%T (T6U)
  • Wavelength accuracy +/- 1nm (T6U)
  • Supplied with either universal pathlength 5 cell changer or fixed path length 8 cell changer as standard
  • Holographic blazed grating 1200lines/mm
  • Local control software for photometric fixed wavelength measurement
  • Easily upgraded to include quantitative analysis, multi-wavelength spectrum & kinetics
  • Built-in cell holder storage
  • Robust modular design with a small footprint
  • Can be used with UV-WIN software (optional)

 

Catalog Number Model Description
T6-1651F T6U Split beam UV-Vis Spectrometer, with 5-cell motorised holder (5-100mm), wavelength range
190-1100nm and 2nm fixed bandwidth. Operating voltage 110 – 240V, 50/60Hz
(Premium PC-controlled software is optional)
T6-1651E (UV/Visible) Split beam UV-Vis Spectrometer, with 8-cell motorised holder (10mm), wavelength range
190-1100nm and 2nm fixed bandwidth. Operating voltage 110 – 240V, 50/60Hz
(Premium PC-controlled software is optional)
T6-1611F T6V Split beam Vis Spectrometer, with 5-cell motorised holder (5-100mm), wavelength range
325-1100nm and 2nm fixed bandwidth. Operating voltage 110V, 50/60Hz
(Premium PC-controlled software is optional)
T6-1611E * (Visible) Split beam Vis Spectrometer, with 8-cell motorised holder (10mm), wavelength range
325-1100nm and 2nm fixed bandwidth. Operating voltage 110V, 50/60Hz
(Premium PC-controlled software is optional)

 

Optical System Split beam
Scan Speed Selectable
Wavelength Range 190-1100 nm
Wavelength Accuracy T6U: ±1 nm ; T6V: ±2 nm
Wavelength Reproducibility T6U≤0.2 nm ; T6V≤0.4 nm
Spectral Bandwidth 2 nm
Photometric Mode Transmittance, Absorbance, Energy
Photometric Range -0.3-3.0 Abs
Photometric Accuracy 0.002 A (0-0.5 A), 0.004 A (0.5-1 A), 0.3 %T (0-100 %T)
Photometric Reproducibility 00.001 A (0-0.5 A), 0.002 A (0.5-1 A), 0.15 %T (0-100 %T)
Photometric Noise 0.001 A (500 nm, 30 min warm-up)
Baseline Flatness 0.002 A (200-1000 nm)
Baseline Stability 0.001 A/h (500 nm, 0 Abs, 2 hr warm-up)
Stray Light T6U: ≤0.05 %T (220 nm NaI, 340 nm NaNO2)
T6V: ≤0.10 %T (220 nm NaI, 340 nm NaNO2)
Standard Functionality Photometric Measurement
(Quantitative, Multi-wavelength, Spectrum and Kinetic measurements with program cards)
Detector Silicon photo diode
Light Source Tungsten Halogen and Deuterium arc lamps
Display Digital LCD
Printer Mini printer
PC Interface RS232
Software Support Local and UV Win
Power Supply Switch mode 95-250 VAC 50-60 Hz
Weight 37 lbs
Dimensions 22 x 20 x 13 in

 